An Entirely New Species

The uMR® 5T represents a real breakthrough in the evolution of MRI, in which the brand-new 5.0T superconducting magnet as well as RF system is designed using state-of-the-art technology and custom sequences are developed to achieve entirely new levels of innovation. It will allow you explore new frontiers in ultra-high field (UHF) MRI by enabling exclusive whole-body 5.0T clinical and research applications. A new species of whole-body MRI says hello to the world.

Unprecedented Ultra-definition Imaging

Revolution Made Real

All-in-one Solution for Clinical and Translational Research

Revolution Made Seamless

Raise the Field Strength without Raising the Fringe Field

Revolution Made Accessible

Unprecedented Ultra-definition Imaging of Jupiter 5.0T

uAIFI Inside

Empowered by the uAIFI Technology Platform, the potential for uMR® 5T is even more anticipated with significant performance enhancements, more powerful imaging capabilities, better workflow, and improved user experience.

uAIFI inside the uMR® Jupiter 5

Unique 8ch Volume Transmit Coil

The 8-channel independently controlled RF transmission architecture allows for dynamic real-time B1 field calibration for different patients, including the amplitude, phase, and waveform of the RF pulse. It effectively solves the problem of UHF B1 inhomogeneity to achieve uniform excitation of the human body, bringing whole-body UHF MR imaging into a clinical setting for the first time.

the 8-channel independently controlled RF transmission architecture inside uMR® Jupiter 5.0T

World's First Whole-body UHF MR Imaging

In the field of UHF MRI, there has been a great deal of attention paid to achieve perfect compatibility between clinical diagnosis and research exploration. To make a difference, the uMR® 5T addresses the three major challenges facing UHF MRI: RF B1 field inhomogeneity, RF safety, and high siting requirement. It will lead to a new era in UHF imaging that will facilitate precise diagnosis and mechanism studies of whole-body diseases, including those of the heart, abdomen, pelvis, and many others.

Whole-body UHF MR Imaging by uMR® Jupiter 5.0T

Ultra-high Performance Gradients

3.5 MW Peak Power Amplifier of UIH

3.5 MW Peak Power

Whole-body UHF MRI gradient performance is now improved to an entirely new level thanks to our state-of-the-art gradient power amplifier which was developed in-house by United Imaging.

diffusion-weighted imaging for the brain

120 mT/m & 200 T/m/s

Significantly increase power of diffusion-weighted imaging and functional MRI with outstanding accuracy and stability for the brain research.

5.0T high-resolution DTI  showing U-fibers

High-resolution DTI

5.0T high-resolution DTI clearly shows U-fibers that are not visible on conventional 3.0T.

5.0T high-resolution BOLD

Accurate BOLD

5.0T high-resolution BOLD more accurately shows the distribution of activated areas on the deep cortex.

Groundbreaking 5.0T Magnet Technology

0.015 ppm @20 DSV Homogeneity and 1.3 ppm @50 DSV Homogeneity powered by 5.0T Magnet Technology

Remarkable Homogeneity

Facilitate whole-body clinical and research applications.
0.015 ppm @20 DSV Homogeneity (Guaranteed).
1.3 ppm @50 DSV Homogeneity (Guaranteed).

UHF MRI with Lowing Sitting Requirement

Low Siting Requirement

The system installation requirements are comparable to those of a conventional 3.0T MRI thanks to its innovative magnet architecture with optimized active shielding design, which makes UHF MRI deployment easier than ever.

Advance Your Clinical Dimensions

TOF MRA 3.0T vs. 5.0T with the same scan parameters

TOF MRA

3.0T vs. 5.0T with the same scan parameters.

SWI: 3.0T vs. 5.0T with the same scan parameters.

SWI

3.0T vs. 5.0T with the same scan parameters.

Hippocampus 3.0T vs. 5.0T with the same scan parameters

Hippocampus

3.0T vs. 5.0T with the same scan parameters.

Kidney 3.0T vs. 5.0T with the same scan parameters

Kidney

3.0T vs. 5.0T with the same scan parameters.

Prostate CSI 3D 3.0T vs. 5.0T with the same scan parameters

Prostate CSI 3D

3.0T vs. 5.0T with the same scan parameters.

Clinical Application

  • Neurology
  • Abdominal Imaging
  • Cardiac Imaging
  • Orthopedics
T1W GRE FSP 3D Voxel Size: 0.7x0.7x0.7 mm3

T1W GRE FSP 3D

Voxel Size: 0.7×0.7×0.7 mm3

T2W FLAIR MATRIX 3D Voxel Size: 0.5×0.5×0.5 mm3

T2W FLAIR MATRIX 3D

Voxel Size: 0.5×0.5×0.5 mm3

T2W FSE TRA/COR Voxel Size:0.25x0.25x2 mm3

T2W FSE TRA/COR

Voxel Size: 0.25×0.25×2 mm3

ASL 3D

Voxel Size: 0.7×0.7×0.7 mm3

DTI Voxel Size: 1x1x1 mm3

DTI

Voxel Size: 1×1×1 mm3

Pancreas T2W FSE FS TRA MicroView

Pancreas T2W FSE FS TRA MicroView

Prostate T2W FSE FS TRA

Prostate T2W FSE FS TRA

Cardiac Imaging

Cardiac Imaging

Knee T1W FSE SAG

Knee T1W FSE SAG

Knee PDW FSE FS SAG

Knee PDW FSE FS SAG

Shoulder PDW FSE FS COR

Shoulder PDW FSE FS COR

Ankle PDW FSE FS SAG

Ankle PDW FSE FS SAG

L-spine T1W FSE SAG

L-spine T1W FSE SAG

L-spine T2W FSE SAG FS

L-spine T2W FSE SAG FS

L-spine T2W FSE SAG

L-spine T2W FSE SAG

L-spine T2W FSE TRA

L-spine T2W FSE TRA

Whole-spine lmaging

Whole-spine Imaging

The product is not commercially available in all countries. Due to regulatory reasons, its future availability cannot be guaranteed.