As an ultra-premium 640-slice CT scanner, uCT 960+ features 16 cm z-axis detector coverage, 0.25 s rotation speed, an ultra-wide 82 cm bore, and a 700 lbs. table weight capacity. Using industry-leading AI-empowered technologies, it launches the era of intelligent imaging, offering precise imaging and ease of use throughout the entire clinical spectrum.

features of uCT 960+
Imaging with Quality

16 cm wide Z-detector
0.5 mm detector acquisition
0.25 s rotation speed

Imaging with AI

uAI Vision
uAI CadioCapture
uAI Dose Modulation

Imaging with Care

82 cm Ultra-wide Bore
318 kg/700 lbs. Table Weight Capacity
60 kVp Capability

16 cm Z-axis Detector Coverage

16 cm Wide Z-detector, 0.5 mm Detector Acquisition in all FOVs.
16 cm Wide Z-detector
TSV Technology

Through-silicon-via (TSV) Technology for ultra-low noise.

3D Anti-Scatter Grid

3D printing technology for effective scattered photon rejection.

Real 3D Full Reconstruction Technology

Cone beam artifacts mitigation associated with wide coverage systems.

16 cm Wide Z-detector

0.25 s Rotation Speed

To deliver superior temporal resolution, freeze the motion in cardiac imaging, and enable 0.25 second rotation speed, we have a one-piece casted gantry structure integrated with a direct drive motor system providing precise rotation speed control.

one-piece casted gantry structure

uAI Vision – AI Empowered Scan workflow

uAI Vision provides an efficient, standardized and personalized scan workflow for each exam.
side view of uCT960
uAI Easy-Positioning

Single-click patient positioning with precise scan range locations based on the selected protocol.

uAI Easy-ISO

Image quality is optimized taking into account the patient's surface dose distribution for every exam.

side view of uCT960

uAI Cardio Capture

Using an intelligent motion correction with an AI-empowered coronary artery algorithm, we have improved the temporal resolution to 25 milliseconds.

 intelligent motion correction

uAI Dose Modulation

An AI-based organ recognition on the scout allows an optimal image noise setting for combined chest and abdomen scanning.
uAl Dose Modulation
Traditional Dose Modulation

Only one target noise level resulting in under-exposing the abdomen or over-exposing the chest.

uAI Dose Modulation

Automatic recognition of the chest and abdomen with an AI-based technology allowing a more optimal noise and optimized dose for the entire patient.

uAl Dose Modulation

Comprehensive Clinical Solutions

Comprehensive Clinical Solutions

Cardiovascular imaging

A medical staff is assisting a patient in front of uCT960.
CardioCapture with 25 ms temporal resolution

Robust, low dose and high quality cardiac imaging within a single heart beat.

Intelligent workflow for cardiac imaging

CardioAssist,
CardioAdapt,
CardioXphase and
CardioCapture.

Fast switching for
cardiovascular imaging

A mixed acquisition of ECG-gated axial scans and non-ECG-gated axial or helical imaging.

A medical staff is assisting a patient in front of uCT960.

Oncology

Two medical staff are doing checkup with a patient.
Dual-Energy Scans

Quantitative and functional measurement with the ability for every scan to be spectral.

Stationary Perfusion Scans

Whole organ perfusion without table motion.

Dynamic Perfusion Scans with up to 40 cm z-coverage

Dynamic perfusion scans with large z-coverage (up to 40 cm) using a variable pitch helix.

Two medical staff are doing checkup with a patient.

Emergency & Trauma

Two medical staff are assisting one patient on uCT960.
Single Rotation Brain Imaging

An entire scan can be completed in half a second to minimize the motion artifacts.

One-Stop Triple Rule Out

One-stop evaluation of coronary arteries, pulmonary arteries, and the aorta in a single exam.

Real Time 3D

MPR or VR preview images in real-time during the acquisition.

Intelligent and Precise Analysis

Comprehensive and accurate intelligent rib fracture analysis.

Two medical staff are assisting one patient on uCT960.

First-class experience

The wide 82 cm bore provides a more comfortable examination experience and a flexible operation space.
a female medical staff is looking after a patient on uCT960+
Low Dose Technology

60 kVp scans reduce radiation dose while maintaining image quality especially for smaller adults and pediatric patients.

High patient throughput

A powerful platform and AI-empowered workflow, a large daily throughput while maintaining high image quality.

a female medical staff is looking after a patient on uCT960+

Clinical Application

Severe Arrhythmia 52-238 bpm Scan type Axial One-beat
Severe Arrhythmia 52-238 bpm Scan type: Axial One-beat
High heart rate with myocardial bridges 99-104 bpm Scan type: Axial One-beat
One-stop cardio-cerebral vascular imaging with a single contrast injection.
One-stop cardio-cerebral vascular imaging with a single contrast injection.
One-stop acquisition for the triple-rule-out.
One-stop acquisition for the triple-rule-out.
The spectral curves demonstrate the different tissues of the bilateral renal lesions.
The spectral curves demonstrate the different tissues of the bilateral renal lesions.
a 82 cm bore and a 318 kg maximum load capacity allowing flexible positioning for obese patients.
a 82 cm bore and a 318 kg maximum load capacity allowing flexible positioning for obese patients.
CBV,CBF,MTT, TTP, and Tmax perfusion data to create a ROI time density curve and one- click generation of parameters.
CBV, CBF, MTT, TTP, and Tmax perfusion data to create a ROI time density curve and one-click generation of parameters.
60 kV scans can lower the radiation dose while improving image quality.